nuclear receptor is one of those subjects where the details matter more than the headlines. This page pulls together the background, the mechanisms, and the practical points readers ask about most.
Updated 2026-06-12. Numbers and descriptions here follow the published literature rather than marketing material.
SR9009 is generally described as poorly soluble in water and more soluble in organic solvents such as dimethyl sulfoxide and ethanol. Stock solutions are commonly prepared in an organic solvent before dilution into an aqueous buffer or vehicle. Precipitation can occur if the organic fraction is reduced too quickly or if the final concentration exceeds the compound's solubility limit. Sonication or gentle warming may aid dissolution in some protocols, but excessive heat can promote degradation. Container material and pH can also influence observed solubility.
For long-term storage, SR9009 is typically kept as a solid at low temperature, protected from moisture and light. Desiccated conditions limit hydrolysis, while opaque containers reduce photochemical breakdown. Solutions are less stable than solids and are often stored frozen in aliquots to avoid repeated freeze-thaw cycles. Stability data are not standardized across all suppliers, so users should rely on certificate-of-analysis information when available. Degradation may appear as color change, precipitate, or decreased chromatographic purity.
Laboratory identification of SR9009 typically relies on chromatographic separation coupled to mass spectrometry, often with ultraviolet detection as a secondary check. Nuclear magnetic resonance spectroscopy can confirm molecular structure when a reference standard is available. Because many suppliers sell the compound as a research chemical, independent identity testing is important for experimental reproducibility. A single retention time is not sufficient proof of identity, especially when related compounds may be present. Purity assessments usually report a percentage based on area normalization.
SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ, also called NR1D1 and NR1D2. These receptors help regulate circadian rhythms and metabolic gene programs. The compound was developed for laboratory research, not as an approved therapeutic. Its identity is distinct from steroid hormones and selective androgen receptor modulators. Scientific interest centers on how REV-ERB activation changes gene expression in cells and animal models.
At the molecular level, SR9009 binds the ligand-binding domain of REV-ERB and strengthens recruitment of corepressor proteins such as NCoR and HDAC3. This increases repression of target genes, including Bmal1 and other clock-controlled and metabolic genes. In rodent studies, such changes have been linked to altered lipid handling, glucose metabolism, and energy expenditure. The precise chain of events between receptor binding and whole-body effects remains an active area of research. Findings in animals do not automatically translate to humans.
Laboratory studies often administer SR9009 by injection because oral absorption appears poor in rodents. Reported pharmacokinetic properties include rapid metabolism and low systemic exposure after oral dosing. Human pharmacokinetic data are sparse, so absorption, distribution, metabolism, and excretion in people are not well defined. Some research explores related REV-ERB compounds with improved drug-like properties. Regulatory approval for any REV-ERB agonist as a human medicine has not been granted to date.
| Property | Value | Notes |
|---|---|---|
| Appearance | White to off-white powder | Visual inspection is not sufficient for identity. |
| Solubility | Soluble in DMSO and ethanol | Low solubility in water; stock solutions use organic solvent. |
| Storage | -20°C, desiccated, protected from light | Limits hydrolysis and photodegradation. |
| Analytical method | HPLC-UV/MS | Used for identity and purity assessment. |
| Synonyms | SR9009, Stenabolic | Naming varies by supplier. |
Analytical identification and purity assessment often use high-performance liquid chromatography with ultraviolet detection or mass spectrometry. Liquid chromatography–tandem mass spectrometry is used to detect and quantify SR9009 in biological matrices, including urine and blood, for anti-doping or pharmacokinetic studies. Nuclear magnetic resonance spectroscopy can confirm molecular structure. Stability depends on form and storage: the solid is generally more stable than solutions, and repeated freeze–thaw cycles may degrade samples. Purity is typically reported as a percentage from a certificate of analysis.
Regulatory treatment of SR9009 varies by country and context. It is not approved as a therapeutic drug by agencies such as the United States Food and Drug Administration or the European Medicines Agency. Sports authorities list it as a prohibited substance; the World Anti-Doping Agency classifies it among hormone and metabolic modulators. Legal status for personal possession or sale differs across jurisdictions, and some countries may restrict it under analog or research chemical laws. Buyers who seek verified material often rely on independent laboratory testing because online product labels may not match contents.
Laboratory samples of SR9009 are typically handled as research chemicals rather than pharmaceuticals. Suppliers usually state that the material is for research use only and not for human or veterinary administration. Storage recommendations generally call for a freezer at approximately −20 °C, protection from light, and a desiccated environment. The solid is often described as a white to off-white powder. Solubility is commonly reported in organic solvents such as dimethyl sulfoxide and ethanol, with low solubility in water.
Handling recommendations for SR9009 in a laboratory setting include storing the solid at low temperature, protected from light and moisture. The compound is often dissolved in dimethyl sulfoxide or ethanol for experiments. Solutions should be prepared with appropriate personal protective equipment and disposed of according to local rules. Stability data for long-term storage are limited, so stock solutions are typically kept cold and used within defined periods. Records of preparation date and concentration support reproducibility.
SR9009 is not approved as a medicine by major regulatory agencies. It is commonly sold as a research chemical, a category that may fall outside customary drug approval and quality rules. In sports, the World Anti-Doping Agency lists SR9009 as a prohibited substance. Athletes who use it can face sanctions if it is detected in a sample. Legal status varies by country, and importation may be restricted. Enforcement practices differ across borders.
Detection of SR9009 in biological samples usually employs liquid chromatography coupled with tandem mass spectrometry. This method can identify the parent compound and sometimes metabolites in urine or blood. Because exposure can be low and clearance may be rapid, sample timing and limits of detection matter. Laboratories validate assays for sensitivity and specificity. Results are interpreted alongside chain-of-custody and quality-control records. Urine is the common matrix for anti-doping analysis, while blood may be used in research settings.
Preclinical reports have linked SR9009 to improved endurance and altered energy expenditure in rodents. Such findings have prompted interest in whether REV-ERB activation can influence skeletal muscle metabolism. However, the reported effects depend on dose, route, and experimental model, and replication across laboratories is limited. Human trials have not established comparable outcomes, so claims about exercise performance remain speculative. The absence of controlled human data is a central limitation in interpreting these observations.
The mechanism of action involves binding to REV-ERB receptors and recruiting corepressor complexes, which represses target gene transcription. This contrasts with many nuclear receptor agonists that activate transcription. Downstream effects may include changes in autophagy, mitochondrial biogenesis, and lipid handling, but the precise pathways remain an active area of study. Whether these molecular events translate into meaningful physiological effects in humans is unresolved. Most evidence comes from cultured cells and rodent models rather than human participants.
=== Availability === The "reference" version of BLOSUM is found in the NCBI toolkits. Both the older (deprecated) NCBI C Toolkit and the current NCBI C++ Toolkit provide the BLOSUM45, BLOSUM50, BLOSUM62, BLOSUM80, and BLOSUM90 matrices. Both also offer APIs for making use of the matrices. The original source code for calculating BLOSUM is also found on the NCBI website, at https://ftp.ncbi.nih.gov/repository/blocks/unix/blosum/. This archive "blosum.tar.Z" represents the original miscalculated version with improved search performance from 1992. The archive also contains pre-calculated BLOSUM outputs at the following similarity levels: "-2" (blosumn), 30, 40, 45, 50, 55, 60, 62, 65, 70, 75, 80, 85, 90, 95, and 100.
=== Human digestion === In the body, most erythritol is absorbed into the bloodstream in the small intestine and then for the most part excreted unchanged in the urine. About 10% enters the colon. In small doses, erythritol does not normally cause laxative effects and gas or bloating, as are often experienced after consumption of other sugar alcohols (such as maltitol, sorbitol, xylitol, and lactitol). About 90% is absorbed before it enters the large intestine, and since erythritol is not digested by intestinal bacteria, the remaining 10% is excreted in the feces. Large doses can cause nausea, stomach rumbling, and watery feces. Doses greater than 0.66 g/kg body weight in males and greater than 0.8 g/kg body weight in females cause laxation, and doses over 50 grams (1.8 oz) cause diarrhea. Rarely, erythritol can cause allergic hives (urticaria).
== Applications == Freeze-drying (lyophilization) cycle development and optimization for pharmaceuticals. Flow diagnostics in hypersonic/re-entry speed research facilities and scramjet combustors. Oxygen tunable diode laser spectrometers play an important role in safety applications in a wide range of industrial processes, for this reason, TDLS are often an integral part of modern chemical plants. The fast response time compared to other technologies for measuring gas composition, and the immunity to many background gasses and environmental conditions makes TDL technology a commonly selected technology for monitoring of combustible gasses in process environments. This technology is employed on flares, in vessel headspace and in other locations where explosive atmospheres must be prevented from forming. According to a 2018 research study, TDL technology is the 4th most commonly selected technology for gas analysis in Chemical Processing.
Sources: en.wikipedia.org
=== Protein stabilization for optimized isolation === Thermofluor pre-screens can be performed that sample a wide range of pH, ionic strength, and additives such as added metal ions and cofactors. The generation of a protein response surface is useful for establishing optimal assay conditions and can frequently lead to improved purification scheme as required to support HTS campaigns and biophysical studies.
=== Auto-ponderomotive guide === An auto-ponderomotive guide is an electrostatic counterpart to a Paul trap. The electron beam is directed into an area of segmented electrodes with alternating negative and positive static voltages placed at half a periodicity
== Chemistry == Flmodafinil is a racemic mixture of (S)-(+)- and (R)-(–)-enantiomers. The (S)-(+) enantiomer has been referred to as JBG1-048 and the (R)-(–) enantiomer has been referred to as JBG1-049.
In addition, they announced plans to conduct a phase 2b study of enobosarm at doses of 3 to 6 mg/day for this purpose in sarcopenic obese or overweight elderly individuals receiving GLP-1 receptor agonists. Enobosarm was developed by GTx, Inc., and is now being developed by Veru, Inc.
Sources: en.wikipedia.org
Liquid chromatography with mass spectrometry is a common approach. Ultraviolet detection and nuclear magnetic resonance can support identification when suitable standards are available.
The solid is generally kept cold, dry, and protected from light. Solutions are often frozen in single-use aliquots to reduce repeated freeze-thaw cycles.
It indicates a material sold for laboratory study, not for human use. The label does not guarantee pharmaceutical purity, sterility, or regulatory approval.
SR9009 is a synthetic research compound that activates the REV-ERBα and REV-ERBβ nuclear receptors. It is not an approved drug and has no established human therapeutic use. Most published biological data come from cell and rodent studies.